Resmed S8 Autoset Spirit Manual
There are three primary sections on this page:. Section One is a list of brief instructions on how to enter the Clinician Setup Menu for common CPAP machines. Section Two is a list of common CPAP Clinician Setup Manuals available via direct download. Section Three is a list of CPAP Clinician Setup Manuals available through email only.Please Keep ReadingPlease help us.Apnea Board is an educational web site and we survive on the kindness of our members. If you have benefited from our CPAP setup instructions, the manuals or the forum, please consider donating a small amount to help us pay for our increased bandwidth hosting costs.We greatly appreciate your help!If you would like to donate using a major credit card, please click on the 'DONATE' button below to use PayPal for your donation (you do not need a PayPal account to use your credit card):Thanks much for anything you can do.If you would rather donate by cash or check, please. Clinician Setup Menu Instructions for Common CPAP Machines:DeVilbiss IntelliPAP 2 CPAP (DV63 Standard Plus & DV64 AutoAdjust): you can enter the setup menu by simultaneously pressing the Blower ON/OFF button, the Ramp button and the Rotary Knob.
English S8 Series II S8 AutoSet Spirit™ II S8 Elite™ II POSITIVE AIRWAY PRESSURE DEVICES Clinical Guide English ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA USA ResMed (UK) Ltd (EU Authorized Representative) 96 Milton Park Abingdon Oxfordshire OX14 4RY UK.
The 3 buttons must be held down until the screen says 'Entering Clinician Menu'. For instructions with pictures, please. To receive the full Clinician Manual via email, please refer to Section Three below.Respironics REMstar Auto (older pre-2007 standard unit, not 'M' series, not the PR System One): you can enter the setup menu by holding down the Ramp button and both of the right and left arrow buttons under the display window, while plugging in the CPAP. The 3 buttons must be held down until the setup screen starts.Respironics REMstar M Series (CPAP or BiPAP): Unplug the power cord from the back of the CPAP machine, then hold down both the left and right arrow keys while simultaneously plugging in the power supply. Once the device beeps twice, release the buttons. After you hear the two beeps, you'll see the word setup in the lower right corner of the LCD screen.
When you select setup you'll be in the clinician's mode where you can adjust every feature of the CPAP machine, including the pressure setting.Philips-Respironics PR System One (REMstar Auto, REMstar DS150, BiPAP ST, BiPAP AVAPS, BiPAP Auto with Bi-Flex, BiPAP Pro with Bi-Flex, REMstar Pro with C-Flex & REMstar Plus): For Setup Instructions with pictures,. Supply power to the device: first, plug the socket end of the AC power cord into the power supply. Then plug the pronged end of the AC power cord into an electrical outlet that is not controlled by a wall switch. Finally, plug the power supply cord's connector into the power inlet on the back of the device.
Once the device is powered, the home screen appears (it is a large box on the screen with four little boxes you can select by turning the control wheel). Turn the wheel to toggle between the 4 options and highlight 'setup'.
Once setup is highlighted press and hold both the control wheel and ramp button on the device for at least 5 seconds. You will hear a double beep and the provider mode screen will appear. Also, you should remove the smart card prior to making adjustments, otherwise it will revert to the previous settings. (note: setup manuals for the REMstar Auto, BiPAP Auto & REMstar Pro machines are available by email, below)Philips-Respironics DreamStation Series Machines (DreamStation Auto BiPAP, DreamStation BiPAP Pro, DreamStation Auto CPAP, DreamStation CPAP Pro, & DreamStation CPAP): For Setup Instructions with pictures,. Supply power to the device: first, plug the socket end of the AC power cord into the power supply. Then plug the pronged end of the AC power cord into an electrical outlet that is not controlled by a wall switch.
Finally, plug the power supply cord's connector into the power inlet on the back of the device. Once the device is powered, press and hold both the control dial and the Ramp button on the device for at least 5 seconds. You are now in Provider Mode. To adjust a setting, rotate the control dial to your desired menu option, then press the control dial to select that setting. Rotate the control dial to change the setting. Press the control dial again to save the change.
Select the 'Home' icon to exit Provider Mode and return to Patient Mode. (note: setup manuals for these machines are available by email, below)Philips-Respironics REMstar SE: Click for instructions on how to enter the Clinician Setup Menu.Respironics SleepEasy: Plug in the machine while simultaneously pressing the plus and minus buttons on top of the machine. The LCD shows the pressure setting along with an icon of a open padlock. To move between options, press the ramp button.
The plus and minus buttons adjust the increments.Respironics Solo LX: Click for instructions on how to enter the Clinician Setup Menu.Respironics REMstar Virtuoso: Click for instructions on how to enter the Clinician Setup Menu.Respironics BiPAP Auto SV & BiPAP ST ( older gray colored model): Click for instructions on how to enter the Clinician Setup Menu.Respironics REMstar Lite: plug the cord into the AC outlet and leave the other end unattached to the machine. Then, firmly hold down both the ramp and power button while plugging the cord into the machine at the same time. When you do so, the 'unlock' icon appears and the blower starts up. You can then navigate through the menu to change pressures.Puritan Bennett GoodKnight 420 Series: Make sure the CPAP machine is plugged in, then find the secret button beneath the 'Go' in the word GoodKnight which appears just above the LCD screen. Press the secret button and the Information Access button simultaneously for 2 or 3 seconds.
Resmed S8 Autoset Spirit Manual 2
The CPAP machine will now be in the provider setup mode. Press the Information Access button to cycle through the list of adjustable settings, and use the arrow buttons to make adjustments.Invacare Polaris EX (and possibly other Invacare models): While in stand-by press and hold both up and down arrows for about 15 seconds. Press up arrow for setup. Use up and down arrows to adjust each setting. Press the large Invacare (enter) button to go to the next setting.
If it asks you 'compliance yes/no?' , select 'yes'. (complete manual via email is listed below)Invacare Polaris LT (you will need a manometer to adjust pressure exactly): Open the top cover using a screwdriver; this will reveal two 'secret' UP and DOWN buttons. Turn the machine on and press both the UP and DOWN buttons simultaneously for 3-5 seconds until the pressure LED light turns on. To reduce pressure, push the DOWN button; to increase pressure, press the UP button. Use a manometer to adjust exact pressure output.Fisher & Paykel HC 234: Enter programming mode by holding down the 'Ramp' (top) button and the 'Next' (Right arrow/bottom button) for three seconds. When you get into the pressure set mode you will first be able to set adjust altitude, which is indicated by a drawing of a mountain range on your screen.
You can change or ignore this setting and then push the 'Next' (Right arrow/bottom button) to advance to pressure setting which will be indicated by the characters 'cm h20 ' on the screen. Use the Up and Down keys to change the pressure setting. Lastly, push the bottom button again to exit programming mode.Fisher & Paykel HC 220 & 220LE: On the side of the machine where the power switch is, you should be able to see a little small cut-out shape like a square, or hidden door. Simply push and pull down and it should slide off, under that there is a black dial that you turn up or down to change the pressure. (note: the right dial, not the left). Right in front of the adjuster knob is an LCD window that will give you the current pressure setting.Fisher & Paykel ICON Auto, Premo & Novo: Start from the 12 o'clock position of the Home Screen. Press and hold the button in the middle of the SmartDial, and use your other hand to turn the SmartDial in a clockwise direction until you return to the 12 o'clock postion.
Do not release the Smart Dial button while turning. Turn the SmartDial back (counter clockwise) one position while still holding down the button and the settings in the Clinician Menu will appear. You can now release the SmartDial button. NOTE: The Clinician Menu will default back to the Patient Menu after 30 seconds, or if the unit is turned off at the power supply. You can manually exit the Clinician Menu by repeating the instructions to enter the menu.2017 Fisher & Paykel SleepStyle Series:.ResMed S8 Compact, S8 Elite, S8 AutoSet Vantage & AutoSet Spirit: Press the right and down arrows simultaneously for about 3 seconds until the word 'clinical' appears.
Select Menu, then use the left and right arrows to cycle through the settings. Use the up and down arrows to make adjustments.ResMed A10 Series (AirSense 10 AutoSet, AutoSet for Her, Elite, CPAP, AirCurve 10 VAuto, S, ST, ASV, & CS PaceWave): For Setup Instructions with pictures,. The 'dial' can be turned or pushed. The button below the screen with the house icon is called the 'home' button.
To access the clinician menu, press the dial and the home buttons simultaneously for 3 seconds. The clinician menu will appear. Select parameter(s) you wish to modify with the dial (push down to select, turn to modify).
When done, press the dial and home buttons for 3 seconds again, or find the 'exit clinical menu' option in the menus. (complete manual available via email, below)ResMed S9 Series (S9 AutoSet, S9 Elite, S9 Escape Auto, S9 Escape, S9 VPAP S, S9 VPAP ST, S9 VPAP Auto & S9 VPAP Adapt): For Setup Instructions with pictures,. Plug in machine and turn the Push Dial until the device is showing the Home position (Home Icon illuminated).
In Home position, press the Push Dial and the Setup Menu buttons down simultaneously for 3 seconds. The clinician menu will appear. Select parameter(s) you wish to modify with the Push Dial (push down to select, turn to modify). When done, select the Home choice again from the displayed menu, push down the Push Dial again and the adjustment is saved. (complete manual available via email, below)ResMed VPAP II: For Setup Instructions,.For the free ResScan and OSCAR data-reporting software,For the free Somnetics software (used for Transcend CPAP machines)please note: you will need to sign into your Apnea Board Forum account to access this page. To register for a free forum account, ResMed S7 Lightweight: For Setup Instructions,.ResMed Moritz S & Moritz ST BiPAP: For Setup Instructions,.Weinmann SOMNOsoft+: Press the ramp-button until 'Soft' can be seen in the Display. While still pressing the ramp-button press the humidifier button, until the pressure-setting-menu appears.Weinmann SOMNOcomfort 2: Press the ramp-button until the display is clear (or 'A' is blinking if Automatic Mode is enabled).
Resmed S8 Autoset Vantage
While still pressing the ramp-button press the humidifier button, until the pressure-setting-menu appears.Weinmann Prisma series with buttons: When in clock mode, press and hold the rightmost buttons (menu and ramp) for a few seconds until MENU CLIN appears. Then press the + (settings) button.Weinmann Prisma series with touch screen: Press and hold the 'info' icon for a few seconds, then choose 'login' to enter setup.Breas PV10 CPAP: For Setup Instructions,.Viasys Orion CPAP: Press both the plus ( + ) button and minus ( -) button simultaneously to get into the clinician setup menu. First set the ramp pressure values, then the ramp time.
After these is the altitude setting (1 - 9 where 1=1,000 feet above sea level); to find your altitude. Next, set the standard pressure in increments of 0.5 cm/H20 of pressure.Evo RemRest 900 Series: Turn on the machine, then turn off the machine. Immediately after that, simultaneously press both arrow buttons.
While holding those 2 buttons down hit the power button to take you to the setup mode. Scroll through the menu using the arrow buttons until you get to the particular setting you want. To change the pressure use the up and down arrow buttons to change the levels. When done press the mode button to apply settings and then power off machine.DeVilbiss 9000 series machines: Turn on the machine, then turn off the machine. Immediately after that, simultaneously press the down arrow button and the ramp buttons. While holding those two buttons down hit the power button to enter the setup mode. Scroll through the menu using the select button until you get to IPAP and EPAP settings.
Use the up and down arrow buttons to change the levels. When done turn off the machine.DeVilbiss RPM Bilevel: To unlock the prescription settings, make sure the blower is OFF (OFF should be shown on the display). While pressing the DELAY and DOWN buttons, press the ON/OFF button to start the blower. The prescription settings are now unlocked and can be changed using the UP and DOWN buttons on the keypad. Press the SELECT button to advance to the next setting.
The first value displayed on the LCD will be the mode. CPAP Clinician Setup Manuals Available via Direct Download: These are Adobe PDF files.
You will need the free Adobe Acrobat Reader, available for downloadIf you're not sure which CPAP model you have, please go to our to identify your machine.(right click on the manual name, then select 'Save File As.' ) to save it to your computer:(This older model has 3 buttons on the top, this is not the PR System One, C-Flex nor the M series) - The 5-button C-flex version is available through email below(not the PR System One)(setup instructions also cover model 604)(older, pre-1999 unit) Please Keep Reading. Please follow these email instructions exactly:If you would like one of the manuals listed above, please send an email to: and put ' Setup Manual' (without the quotes) in the subject line. Then, let us know in the body of your email which of the listed manuals you would like us to email to you.
It is best if you copy the exact manual name from the above list and paste it into your email to make sure you receive the correct manual.LIMIT: Two (2) Clinician Manuals per individual.(If you request more than two manuals, your request will be discarded)Your manual should then be sent to you within a day or two (we try to send out manuals daily, except around holidays). Keep in mind- these files are very large- your email provider must be able to receive files up to and including 13 MB (megabytes) in size for this to work.
Resmed S8 Autoset Spirit Manual Download
If you need a free email account that will handle large file sizes, we suggest. If you have not received your file in a few days, you may wish to check your 'junk email' folder - since we're sending a large file, sometimes our emails get marked incorrectly as 'junk mail'.Please check carefully - If your CPAP is not on the above list, we do not have a manual for it, so you may wish to to see if anyone else has a copy they can email to you. Note to REMstar Auto, REMstar Pro & REMstar Plus owners:When requesting a manual, in addition to your model type, please tell us which REMstar series you have, according to this picture:If you're not sure which CPAP model you have, please go to our to identify your machine.Attention Medical Professionals & Employees of Commercial Entities:We send manuals free-of-charge to individual Sleep Apnea patients for their own personal educational use.If you work for a commercial entity or are employed by a medical facility, please read our.Please Keep Reading. Can't find your manual here? Suggestion: If you're trying to change your CPAP pressure but don't find your manual listed, try following the instructions for another machine made by the same manufacturer - in some cases, the procedure for getting into the clinician setup menu is the same. If you're not sure which CPAP model you have, please go to our to identify your machine.For a detailed explanation of how to determine the optimum pressure on your CPAP machine,.There you have it. Take control of your Sleep Apnea, and be safe.Thanks for visiting Apnea Board!Please send us your manual: If you have a setup manual or instructions on how to enter the setup menu for a machine we don't have listed here, please help us, and email it to This email address is being protected from spambots.
You need JavaScript enabled to view it. And we will make sure it gets posted here. Thanks!(This page includes CPAP Service 'Repair' Manuals, plus other files of interest to Sleep Apnea patients).This web page was last updated on: July 30, 2019For our current update history, beginning in 2012.
CPAP TreatmentCPAP therapy is the most effective noninvasive treatment for obstructive sleep apnea. The CPAP Pro systems consist of several CPAP accessories: CPAP Pro machines (flow generators), air tubing and a CPAP headgear (usually a nasal mask). The CPAP Pro machine pushes air through the tubing and nasal mask.The air passes through your nose and into the throat, where the slight pressure keeps the upper airway open. The low air pressure does not interfere with breathing though some patients need a few nights to get used to the sensation of positive airflow. Many clinicians describe the CPAP PRO therapy as a pneumatic splint, literally meaning an air splint to hold an open throat.The pneumatically splinted upper airway process is performed when the tongue and soft tissue have fallen to the back of the throat, but the pressure of the air pumped in by the CPAP Pro machine holds the upper airway open.Obstructive Sleep ApneaObstructive Sleep Apnea Syndrome is a sleep disorder which characterized by obstruction of upper airways. Obstructive sleep apnea usually associated with a reduction in blood oxygen saturation. In this situation the airway becomes obstructed at several possible sites.The upper airway can be obstructed by excess tissue in the airway, large tonsils and large tongue.
It also includes the airway muscles relaxing and collapsing during sleep. Another site of obstruction can be the nasal passages. Spirit II / Vantage IIWhat is it?The S8 AutoSet a Vantage II(also known as ResMed AutoSet Spirit II) is the automatic positive airway pressure (APAP) device in the S8 series. It is designed for use in the sleep center or home, for the treatment of obstructive sleep apnea in adults.The S8 Vantage II uses AutoSet technology that sets the air pressure automatically to the patient's needs.